NICET ITFAS-Level-1 Inspection and Testing of Fire Alarm Systems Level I Exam Exam Practice Test

Inspection and Testing of Fire Alarm Systems Level I Exam Questions and Answers

Testing Engine

  • Product Type: Testing Engine
$37.5  $124.99

PDF Study Guide

  • Product Type: PDF Study Guide
$33  $109.99
Question 1

Verification of a DACT’s trouble signal to the fire alarm shall be received within a maximum of how many minutes when the primary telephone line is disconnected?

Options:

A.

2

B.

3

C.

4

D.

5

Question 2

Which two of the following are needed to perform a periodic test of a projected beam type smoke detector? (Choose two.)

Options:

A.

Blocking the transmitter

B.

Introducing smoke

C.

Using a listed test switch

D.

Using an optical filter

Question 3

What is the inspection frequency of supervising station alarm system transmitters?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Question 4

Secondary power for the fire alarm primary power supply shall be tested under which load?

Options:

A.

Half load

B.

Maximum load

C.

Minimum load

D.

Supervisory load

Question 5

After 15 years, what should be done with nonrestorable, spot-type heat detectors in lieu of testing?

Options:

A.

Replace 2 devices

B.

Replace 5 devices

C.

Replace 15 devices

D.

Replace all devices

Question 6

After the secondary power supply has operated the fire alarm system under quiescent load,the secondary power shall be capable of operating all alarm notification appliances for which length of time?

Options:

A.

5 minutes

B.

10 minutes

C.

1 hour

D.

24 hours

Question 7

What is the testing frequency of an engine driven generator?

Options:

A.

Weekly

B.

Monthly

C.

Semiannually

D.

Annually

Question 8

A disconnection of the primary phone line shall cause which of the following events to occur?

Options:

A.

Activation of notification appliance

B.

Local annunciation only

C.

Notification via secondary phone line

D.

Supervisory condition

Question 9

What is the maximum travel distance between two fire alarm boxes measured horizontally on the same floor?

Options:

A.

30 feet (9.1 meters)

B.

60 feet (18.3 meters)

C.

90 feet (27 meters)

D.

200 feet (61 meters)

Question 10

The inspection phase, as opposed to the testing phase, of system control equipment should concentrate on which of the following tasks?

Options:

A.

Activation of all initiating devices

B.

Operational reliability only

C.

Proof of signals at monitoring facility

D.

Visual inspection only

Question 11

Which three of the following parties gets notified that the system has been restored? (Choose three.)

Options:

A.

Authority Having Jurisdiction

B.

Building occupants

C.

First responders

D.

Monitoring organization

Question 12

Within a fire alarm control unit, what is the maximum delay in seconds for alarm system responses after the initiation device has been activated?

Options:

A.

10

B.

15

C.

30

D.

60

Question 13

The minimum supervising station signaling requirement for a fire alarm system that monitors a sprinkler flow and tamper switch shall include which set of signals?

Options:

A.

Alarm, trouble, and phone line failure

B.

Alarm, trouble, and supervisory

C.

Alarm, trouble, supervisory, and daily test

D.

Alarm, trouble, supervisory, and primary power

Question 14

When the main power is disconnected, how long should a power supply with emergency voice communication systems work in alarm mode?

Options:

A.

Maximum of 5 minutes

B.

Maximum of 15 minutes

C.

Minimum of 5 minutes

D.

Minimum of 15 minutes

Question 15

How is a projected beam detector inspected?

Options:

A.

Check for obstruction

B.

Introduce smoke

C.

Remote test switch

D.

Use an optical filter

Question 16

After 15 years from initial installation, all fixed-temperature, nonrestorable heat detectors shall be replaced or have how many detectors per 100 laboratories tested?

Options:

A.

2

B.

4

C.

6

D.

8

Question 17

Which two of the following should occur when a signal silence switch for a notification alarm is activated? (Choose two.)

Options:

A.

Audible appliances are deactivated.

B.

Door holders are deactivated.

C.

HVAC shutdown is deactivated.

D.

Visible appliances are deactivated.

Question 18

An off-normal signal shall be initiated during which of the following travel distances of the valve control apparatus from its normal position?

Options:

A.

1/5

B.

1/4

C.

1/3

D.

1/2

Question 19

At which height above the floor is the sound level measured for public and private modeaudible devices?

Options:

A.

2.5 feet (0.7 meter)

B.

5.0 feet (1.5 meters)

C.

7.5 feet (2.3 meters)

D.

8.0 feet (2.4 meters)

Question 20

Visible and audible trouble signals shall be indicated at which two of the following locations? (Choose two.)

Options:

A.

Alarm company office

B.

Emergency command center

C.

Fire alarm control unit

D.

Fire department headquarters

Question 21

How often should radio transmitters be inspected?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Question 22

According to NFPA 72, which date shall be marked on batteries?

Options:

A.

Month and year of expiration

B.

Month and year of inspection

C.

Month and year of installation

D.

Month and year of manufacture

Question 23

Which three of the following test methods are used to ensure that the smoke detectors are within their sensitivity range? (Choose three.)

Options:

A.

AHJ approved calibrated test

B.

Listed control equipment arranged for testing

C.

Manufacturer's calibrated sensitivity test instrument

D.

Test approved by the engineer

Question 24

Which of the following situations is considered an impairment?

Options:

A.

Closed sprinkler valve

B.

Intelligible audibility

C.

Smoke detector within 4 feet of a return air opening

D.

Smoke detector within 4 feet of an air supply diffuser

Question 25

Primary power supplies shall be functionally tested at which interval?

Options:

A.

Every month

B.

Every 3 months

C.

Every 6 months

D.

Every 12 months