Huawei H12-411_V2.0 HCIA-Data Center Facility V2.0 Exam Practice Test

Page: 1 / 20
Total 204 questions

HCIA-Data Center Facility V2.0 Questions and Answers

Testing Engine

  • Product Type: Testing Engine
$42  $119.99

PDF Study Guide

  • Product Type: PDF Study Guide
$36.75  $104.99
Question 1

PUE The closer the value ____________, indicating that the energy efficiency status of the data center is good.

Options:

Question 2

During the construction process, carry out low-voltage live work ____________, should be used ____________ .

Options:

Question 3

The following ____________ air supply methods mainly use process air conditioners that have a large amount of waste heat to be taken away from the lower working area.

Options:

Question 4

In the battery structure, the ____________ component functions to remove excess gas.

Options:

Question 5

It can be implemented in the alarm management function of the dynamic environment monitoring system ____________ .

Options:

Question 6

The function of the following () parts is to help with oil return.

Options:

A.

liquid lens

B.

oil sight glass

C.

Oil trap

D.

reverse bend

Question 7

During the construction process, if there is an object falling or hitting, it should be used ____________ .

Options:

Question 8

The following ____________ are not harmful effects of electric current on the human body.

Options:

Question 9

At a certain atmospheric pressure and water vapor content, the air is cooled down. When the air reaches saturation, it will continue to cool down. The temperature at the time of condensation is ____________ .

Options:

Question 10

During the construction process, work in contact with sharp instruments and use ____________ .

Options:

Question 11

Under the same load conditions,ups The backup time is mainly determined by the battery capacity and the number of battery cells. The larger the battery capacity, the longer the backup time.

Options:

A.

True

B.

False

Question 12

Huawei Monitoring System NETECO Support hierarchical network management function.

Options:

A.

True

B.

False

Question 13

There are three different classifications of grounding forms in low-voltage power distribution systems ____________, where the first capital letter represents ____________ .

Options:

Question 14

In the low-voltage power distribution system,PE The function of the line is to provide a path for the fault current when the power supply system fails.

Options:

A.

True

B.

False

Question 15

The possible functions of the dynamic loop monitoring system include ____________ .

Options:

Question 16

Parameter representation upsPollution to the power grid.

Options:

A.

Output power factor

B.

Input current harmonics

C.

Overload capacity

D.

efficient

Question 17

The following ____________ Yes UPS N The advantages of the system.

Options:

Question 18

During the battery installation process, the maintenance channel of the high-voltage battery pack used should be insulated.

Options:

A.

True

B.

False

Question 19

For valve-regulated lead-acid batteries, the function of the safety valve is ____________ .

Options:

Question 20

The fuse can protect personal safety when the equipment leaks.

Options:

A.

True

B.

False

Question 21

In the dynamic ring monitoring system, it can be used to store high-definition images and provide large-scale storage media. The equipment used for long-term storage of video recording is ____________ .

Options:

Question 22

Data center energy consumption mainly comes from environmental equipment, lighting systems, refrigeration systems, power distribution systems, etc. How to reduce the energy consumed by ____________ is the key to solving data center energy conservation in the industry.

Options:

Question 23

ABC Circuit breakers are mainly used IT Load front end, such as ups Inside the output cabinet.

Options:

A.

True

B.

False

Question 24

Huawei Monitoring System NETECO The northbound interface can be accessed ____________ .

Options:

Question 25

____________ is a fire detector that detects smoke particles.

Options:

Question 26

The following ____________ Yes UPS 2N. The advantages of the system.

Options:

Question 27

The device cannot be connected to the southbound interface of the dynamic environment monitoring system.

Options:

A.

Precision air conditioner

B.

UPS

C.

Access control equipment

D.

Upper-level network management

Question 28

____________ Yes upsThe unit of rated capacity.

Options:

Question 29

Compared with comfort air conditioners, special air conditioners for computer rooms have the following advantages ____________ .

Options:

Question 30

The core components of the refrigeration system mainly include ____________ .

Options:

Page: 1 / 20
Total 204 questions