Question 1

Which one of the following represents the three elements (oxygen, heat and fuel) to interact in order for the fire to exist?

Options:

A.

The Fire Hexagon

B.

The Fire Class

C.

The Fire Triangle

D.

The Fire Technology

Question 2

When dealing with glass door racks, cool air is injected into the rack from:

Options:

A.

The rear door in a downflow direction.

B.

The front door in a downflow direction.

C.

The top of the rack through the fans and vents mounted inside the rack.

D.

The bottom of the rack.

Question 3

Which type of Humidifier rapidly vibrates waster to create a fog or mist?

Options:

A.

Infrared Humidifier

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Question 4

Mean time between failures is best considered a measure of:

Options:

A.

Size

B.

Cost

C.

Duration

D.

Reliability

Question 5

Which one of the following is an example of Indirect Cost?

Options:

A.

Legal fees

B.

Damaged brand perception

C.

System recovery

D.

Cost revenues

Question 6

Starting from which Rating does the requirement of Concurrently Maintainability becomes relevant?

Options:

A.

Rated-4

B.

Rated-3

C.

Rated-2

D.

Rated-1

Question 7

Which type of Fire Detection Device is recommended for protecting a Data Center?

Options:

A.

Heat detector

B.

Smoke detector

C.

Flame detector

D.

None of the above

Question 8

What is a requirement of an FM200 (HFC-227) installation?

Options:

A.

It is a high-pressure gas; therefore nozzles must be mounted with two brackets.

B.

Drainage system under the raised floor.

C.

Install the gas containers (tanks) close to the data centre.

D.

Install pre-action sprinklers in the same room as the FM200.

Question 9

Cost of Downtime can be classified as.

Options:

A.

Direct and Indirect

B.

Up and Down

C.

Mean and Median

D.

Classified and Declassified

Question 10

The temperature and humidity values indicated on the display of the Computer room air conditioner unit are the values measured at which point?

Options:

A.

It is the average value between the intake and exhaust (outlet) of the air conditioner.

B.

It is the value measured at the intake of the air conditioner.

C.

It is the value measured at the exhaust (outlet) of the air conditioner.

D.

It is the value measured at the front of the rack of the aisle the air conditioner is situated.

Question 11

What factor should be considered when placing fluorescent lighting in the data centre?

Options:

A.

Fluorescent lights should not be connected to the back-up generator.

B.

Fluorescent lights should only be installed in equipment supporting areas and not in the Computer/Server room.

C.

Fluorescent lights should not be connected to the mains power supply.

D.

Fluorescent lights should not be connected to the same UPS that supports the ICT equipment.

Question 12

is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period.

Options:

A.

MTBF

B.

MCBF

C.

MLBF

D.

MTTR

Question 13

Sprinkler heads used in computer rooms activate at what temperature?

Options:

A.

57 °C (135 °F)

B.

27 °C (81 °F)

C.

70 C (158 °F)

D.

Only on direct contact with a flame

Question 14

Which is the most damaging type of floor load?

Options:

A.

Concentrated Load / Point Load (CP/ PL)

B.

Uniformly Distributed Load (UDL)

C.

Rolling Load (RL)

D.

All loads are equally damaging to raised floor tiles

Question 15

Does shielded twisted pair network cabling provide protection against EMF from power cables?

Options:

A.

Yes, but only if the power cable is placed in a tre-foil cable arrangement.

B.

Yes, as the shielding for twisted pair network cabling is specifically design for low frequency EMF protection.

C.

No, the shielding is designed for alien cross-talk between network cables, it provides no or little protection against low frequency EMF.

D.

No, the shielding for twisted pair network cabling is for physical protection against vandalism and accidental cutting of the cable.

Question 16

What is the current recommended temperature for ICT equipment as described in the ASHREA TC 9.9 guideline?

Options:

A.

8-18 C (46.4 -64.4 °F)

B.

20-40 °C (68 - 104 °F)

C.

18-27 C (64.4 - 80.6°F)

D.

25-45 °C (77 - 113 °F)

Question 17

Which one of the following is a device that uses circulating chilled water to remove heat?

Options:

A.

Computer Room Air Handling Unit (CRAH)

B.

Computer Room Air System Unit (CRAS)

C.

Computer Room Air Suspension Unit (CRAS)

D.

Computer Room Air Suppression Unit (CRAS)

Question 18

Escape route signage should be placed where?

Options:

A.

Only at emergency escape doors

B.

Only at the main entrance of the data centre building

C.

At every door providing a pathway

D.

At every door including riser doors, doors of storage closets etc.

Question 19

is the degree to which a system or component is operational and accessibility when required for use.

Options:

A.

Scalability

B.

Agility

C.

Reliability

D.

Availability

Question 20

Which one of the following is a Natural Disaster?

Options:

A.

Grid Failure

B.

Blackouts

C.

Hurricanes

D.

Human Error

Question 21

From the list below, which sensor detects smoke the fastest?

Options:

A.

Photoelectric detector

B.

VESDA/HSSD

C.

lonization detector

D.

Sprinkler bulbs