An MX7000 administrator has been tasked to create a Scalable Fabric Architecture on a 3 chassis setup using Fabric B.

Which IOM configuration is recommended?

Options:

A.

Chassis 1 - Slot B1: MX9116n; Slot B2: MX9116nChassis 2 - Slot B1: MX5108n; Slot B2: MX5108nChassis 3 - Slot B1: MX5108n; Slot B2: MX5108n

B.

Chassis 1 - Slot B1: MX7116n; Slot B2: MX7116nChassis 2 - Slot B1: MX7116n; Slot B2: MX7116nChassis 3 - Slot B1: MX9116n; Slot B2: MX9116n

C.

Chassis 1 - Slot B1: MX9116n; Slot B2: MX7116nChassis 2 - Slot B1: MX7116n; Slot B2: MX9116nChassis 3 - Slot B1: MX7116n; Slot B2: MX7116n

D.

Chassis 1 - Slot B1: MX9116n; Slot B2: MX5108nChassis 2 - Slot B1: MX5108n; Slot B2: MX9116nChassis 3 - Slot B1: MX5108n; Slot B2: MX5108n

Question 2

Refer to the exhibit.

What is shown?

Options:

A.

MX5000s

B.

MX5108n

C.

MX5016s

D.

MXG610s

Question 3

Match each feature with its associated PowerEdge server management tool.

Options:

Question 4

Which command(s) is supported in the current PowerEdge MX Redfish implementation?

Options:

A.

PUT and DELETE

B.

PUT only

C.

HEAD and PUT

D.

GET and DELETE

Question 5

An administrator is configuring a fully populated MX5016s storage sled to be accessed by four MX740c compute sleds. Each compute sled has an H745P Jumbo PERC installed. The disks in the storage sled are evenly distributed across all compute sleds using a Drive-Assigned storage configuration.

What is the maximum number of disks that each compute sled can detect from the MX5016s?

Options:

A.

1

B.

2

C.

4

D.

16

Question 6

Which I/O module is supported for Fabric B?

Options:

A.

MX5016s

B.

MSG610s

C.

MX5000s

D.

MX5108n

Question 7

A company receives their first MX7000 chassis. They connect all the provided power supply cables into two different PDUs on different power grids for redundancy. Each of the six power supplies is cabled and has green LEDs. One Management Module is present along with all system fans. Grid redundancy is configured as the power redundancy mode. The chassis is fully populated with six compute sleds and one IOM but only two of the six sleds will power on.

What is the possible reason for this issue?

Options:

A.

An additional IOM is required to power on and manage the remaining sleds.

B.

Two Management Modules are required to power on the populated chassis.

C.

Power supply unit redundancy policy was not used.

D.

Mixed high line and low line AC inputs in the same chassis is not supported.

Question 8

What is a benefit of using scalable fabric architecture in the MX7000?

Options:

A.

Management of all servers and fabrics is done from the last chassis in the fabric

B.

Management of all fabrics is done from the third fabric in the chassis

C.

Management of all servers and fabrics is done from the lead chassis

D.

Management of all fabrics is done from the last chassis in the fabric

Page: 1 / 5